AFI5

🧪 What This Data Means — For Quick Client Selection

  • Wide measurement ranges mean AFI5 can handle everything—from ultra-low conductivity DM water to high-TDS industrial streams.

  • Dual analog outputs allow simultaneous monitoring of conductivity + temperature or conductivity + TDS—helpful in RO skids and dosing skids.

  • Modbus RTU enables seamless integration with PLC/SCADA, making it suitable for modern automated plants.

  • Advanced temperature compensation ensures accuracy in fast-changing processes like CIP, boiler feed, and cooling water loops.

  • High-temperature & high-pressure capability makes it usable in hot water, CIP caustic/acid lines, and elevated-pressure utilities.

  • 4-electrode sensors minimize polarization effects, offering stability for high-conductivity or contaminated water—while 2-electrode cells suit clean applications.

  • Configurable relays allow direct local control for alarms or pump automation without PLC dependency.

  • IP67 rugged housing makes AFI5 suitable for outdoor plants, STPs, chemical dosing rooms, and humid utility areas.

  • Flexible calibration ensures easy on-site accuracy checks with standard solutions—ideal for operators and maintenance teams.

Description

Baumer AFI5 is an advanced conductivity/TDS transmitter with high-resolution signal processing, multi-range capability, and superior temperature compensation. Designed for process plants requiring continuous, reliable water-quality monitoring, it supports 2-/4-electrode cells, Modbus communication, and dual analog outputs. Ideal for RO/DM units, CIP skids, ETP/STP, and utility water systems.

🔧 Baumer AFI5 — Key Technical Data & Selection Parameters

Parameter Specification / Details
Measurement Range 0…2000 µS/cm, 0…20 mS/cm, 0…200 mS/cm (sensor-dependent)
TDS Measurement Programmable TDS factor (0.30–1.00)
Electrode Type 2-electrode / 4-electrode conductivity cells
Cell Constants K = 0.1 / 1.0 / 10.0
Temperature Compensation Automatic via PT100/PT1000/NTC; configurable algorithms
Accuracy ±1% of reading (depending on sensor & conductivity range)
Process Temperature –20 °C to +130 °C (electrode-dependent)
Process Pressure Up to 25 bar (high-pressure-rated sensors)
Outputs 4–20 mA (1 or 2 channels), pulse, relay alarms
Digital Communication Modbus RTU (RS485) available
Display High-contrast LCD with multi-parameter indication
Power Supply 24 VDC loop-powered or 110–230 VAC versions
Housing IP65 / IP67 field-mount enclosure
Calibration 1-point / 2-point / cell constant verification
Materials SS316L / PVDF / Graphite sensor options
Typical Applications RO permeate, DM water, CIP return, boiler feed, cooling towers, ETP/STP, chemical dosing, beverage & pharma utilities