Aqua 4 Trans

🧪 What This Data Means — For Quick Client Selection

  • Wide measurement range (0–200 mS/cm) makes Aqua 4Trans suitable for both ultra-pure water and high-TDS industrial streams—ideal for one-transmitter multi-stage RO systems.

  • Dual 4–20 mA isolated loops allow independent transmission of conductivity and temperature/TDS to PLC/SCADA, reducing wiring and module cost.

  • MODBUS RS485 support enables seamless integration with automation systems in RO skids, boiler houses, and ETP panels.

  • Four cell constant options ensure correct selection for pure water (0.01 K), low conductivity (0.1 K), general process water (1.0 K), and highly contaminated water (10 K).

  • Inductive sensor compatibility provides excellent performance in fouling, high-TDS, and chemically aggressive environments.

  • IP65 field enclosure ensures reliability outdoors or in humid plant areas like cooling towers, DM rooms, and STP/ETP sites.

  • Relay alarms enable direct pump/motor control, RO reject diversion, or high-TDS trip functions without additional hardware.

  • High temperature capability supports boiler water and condensate monitoring up to 120 °C with correct probes.

Description

 Aqua 4Trans is a multi-parameter conductivity/TDS transmitter designed for high-precision industrial water analysis. It supports multiple sensor types, offers advanced temperature compensation, dual analog outputs, relay controls, and robust IP65 construction. Ideal for RO/DM plants, boiler water, cooling towers, ETP/STP, chemical processes, and continuous online monitoring.

🔧 Aqua 4Trans — Key Technical Data & Selection Parameters

Parameter Specification / Details
Measurement Range 0–200 mS/cm (auto/manual range selection)
TDS Range Up to 200,000 ppm (dependent on factor)
Cell Constant Options 0.01 / 0.1 / 1.0 / 10.0 (broad application coverage)
Temperature Compensation Auto/Manual, NTC / Pt100 / Pt1000
Accuracy ±0.5% of reading (sensor dependent)
Display Large backlit LCD, multi-parameter
Outputs Dual 4–20 mA (isolated) for conductivity + temperature/TDS
Communication MODBUS RS485 (optional)
Relay Outputs High/Low alarms for process control
Enclosure IP65 weatherproof field / panel mount
Calibration 1-point / 2-point using standard solutions
Sensor Compatibility Contact-type & inductive conductivity sensors
Process Temperature Up to 120 °C (with suitable probe)
Power Supply 85–265 V AC or 24 V DC
Typical Applications DM/RO plants, boiler/condensate monitoring, cooling towers, process water, ETP/STP, pharma pre-treatment

Reviews

There are no reviews yet.

Be the first to review “Aqua 4 Trans”

Your email address will not be published. Required fields are marked *